Boiler problems

Ideal L2 fault code: what it means

Your Ideal boiler is showing L2 and has locked out. Here is what the code means, what you can safely check and when to call us.

4 min read

L2 is an ignition lockout code on Ideal boilers, including the Logic, Logic Max and Vogue ranges. It means the boiler has made several attempts to light without detecting a flame, and has locked itself out for safety.

Never remove the boiler casing or touch any gas parts yourself. Work inside a gas appliance is illegal unless you are Gas Safe registered, and it can be dangerous.

What causes L2?

The boiler needs gas, a spark and a clear path for flue gases and condensate before it will light. L2 appears when one of those is missing. Common causes include:

  • An interrupted gas supply, or a prepayment meter with no credit
  • A frozen condensate pipe, one of the most common causes of L2 in winter
  • A worn or poorly positioned ignition electrode
  • Low gas pressure reaching the boiler
  • A faulty gas valve, fan or PCB inside the boiler

Some of these you can check yourself. Faults inside the boiler need a Gas Safe registered engineer.

Safe checks you can make

Check your gas supply

Try your gas hob or another gas appliance. If nothing works, check that the valve at the gas meter is on and, if you have a prepayment meter, that there is credit. If neighbours have lost gas too, call the National Gas Emergency line on 0800 111 999.

Check the condensate pipe

In freezing weather, look at the plastic pipe running from the boiler to an outside drain. If it is frozen and you can reach it safely at ground level, pour warm, not boiling, water along it to thaw it. Do not climb ladders.

Reset the boiler once

Once you have checked the gas and the condensate pipe, press the reset button as described in your manual and wait for the boiler to try again. If L2 returns, stop resetting it and call an engineer.

When to call a Gas Safe engineer

Call us if L2 returns after one reset, if your gas supply is fine and the condensate pipe is clear, or if the boiler locks out every few days. Repeated lockouts usually mean a part inside the boiler is failing, and it needs testing by a Gas Safe registered engineer.

Our engineers repair Ideal boilers across Newcastle upon Tyne, North Tyneside, Gateshead and surrounding areas. Find out more on our Ideal boiler repair page, or see our boiler repairs page. A repair visit is £85, covering the call out, diagnosis and first hour of labour.

If you smell gas, do not reset the boiler. Open windows and doors, do not use electrical switches, turn the gas off at the meter if it is safe to do so and call the National Gas Emergency line on 0800 111 999.

More help with fault codes

Our guide to boiler fault codes explained covers the other common code families, including low pressure and overheat faults.